  This product is used for flow measurement of various conductive liquids in industrial engineering, such as corrosive media such as acids, alkalis, salts, etc; Various flammable and explosive media; The measurement of various slurry flow rates in wastewater treatment, chemical, food, pharmaceutical and other industries has formed a unique application field.

  1、 Characteristics:

  The sensor adopts an integral welded structure with good sealing performance;

  The structure is simple and reliable, with no moving parts inside and almost no pressure loss;

  The measurement accuracy is not affected by changes in physical parameters such as pressure, temperature, density, viscosity, etc. of the measured medium; Accuracy is not sensitive to changes in velocity distribution (except for vortices);

  Equipped with conductivity measurement function, it can distinguish whether the sensor is empty or not; Adopting a 16 bit embedded microprocessor, it has fast computing speed and high accuracy; There are two integrators inside, which display forward and reverse accumulation and difference accumulation respectively; Capable of outputting RS485 or RS232C digital communication signals.

  2、 Technical parameters:

  Nominal diameter (mm): Pipeline PTFE lining: DN10~DN600 Pipeline rubber lining: DN40~DN1200

  Flow direction: positive, negative, net flow

  Range ratio: 150:1

  Repetitive error: ± 0.1% of the measured value

  Accuracy level: Pipeline type: 0.5 level, 1.0 level

  Temperature of the tested medium: ordinary rubber lining: -20 to+60 ℃

  High temperature rubber lining: -20 to+90 ℃

  PTFE lining: -30 to+100 ℃

  High temperature PTFE lining: -20 to+180 ℃

  Rated working pressure: (high pressure can be customized) DN6-DN80: ≤ 1.6MPa DN100-DN250: ≤ 1.0MPa

  DN300-DN1200:≤0.6MPa

  Conductivity range: The conductivity of the measured fluid is ≥ 5 μ s/cm

  Current output, load resistance: 0-10mA: 0-1.5k Ω 4-20mA: 0-750k Ω

  Digital frequency output: The upper limit of the output frequency can be set within 1-5000Hz with a transistor collector open circuit bidirectional output with photoelectric isolation.

  Power supply: AC220V or DC24V

  3、 Selection of installation location:

  1. The flow direction indicator on the sensor must match the direction of the measured medium flow inside the pipeline.

  2. The installation position must ensure that the measuring tube is filled with the measured medium.

  3. Choose a location with smaller fluid flow impulse, which should be away from the pump and local resistance components (valves, elbows, etc.)

  4. When measuring two-phase fluids, a location that is not prone to phase separation should be selected.

  5. Installation in areas with negative pressure inside the pipe should be avoided as much as possible.

  6. When the measured medium easily causes adhesion and scaling on the inner wall of the electrode and measuring tube, it is recommended that the flow velocity inside the measuring tube should not be less than 2m/s.